Concrete RH Probe Testing for Flooring Contractors

Know Your Slab's Moisture Conditions Before Flooring Installation

Concrete can retain moisture long after its surface appears dry. Excess moisture can affect flooring adhesives, contribute to bond failure, and damage finished flooring.

Reliant Testing Engineers, Inc. provides in-situ relative humidity (RH) probe testing in accordance with ASTM F2170 to help flooring contractors evaluate concrete slab moisture conditions before installation.

We work with commercial flooring contractors, general contractors, and construction teams throughout Southern California to coordinate testing and provide documented results for project review.

ASTM F2170 Concrete Moisture Testing

ASTM F2170 measures relative humidity within a concrete slab using in-situ probes installed at a specified depth. The results provide information about internal moisture conditions for comparison with flooring and adhesive manufacturer requirements.

Our testing process includes:

  • Project coordination: Review the project location, slab thickness, floor area, and testing schedule.
  • RH probe installation: Install probes at designated locations in accordance with the applicable test procedure.
  • Moisture readings: Allow the required equilibration period and collect official readings.
  • Documentation: Compile the test results for review by your project team.

ASTM F2170 requires a minimum 24-hour equilibration period after probe installation before official readings are taken. Plan your testing schedule accordingly.

Call 714-556-5867 to schedule testing.

How Many RH Tests Does Your Project Need?

ASTM F2170 generally requires three test locations for the first 1,000 square feet of concrete floor area, plus one additional location for each additional 1,000 square feet or fraction thereof.

Concrete floor area

Minimum test locations

Up to 1,000 sq. ft.

3

1,001–2,000 sq. ft.

4

2,001–3,000 sq. ft.

5

5,001–6,000 sq. ft.

8

Project specifications and site conditions may require additional testing.


When requesting a quote, have your project address, approximate square footage, slab thickness, and anticipated flooring installation date available.


These details help us coordinate the testing scope and schedule.

Why Test Before Installing Flooring?

Moisture testing gives your project team documented information about the slab before flooring materials and adhesives are installed.

Depending on the flooring system and site conditions, excess moisture can contribute to:

  • Adhesive deterioration and bond failure.
  • Flooring debonding, bubbling, or finish damage.
  • Installation delays and costly remediation.

Test results should be evaluated against the applicable flooring manufacturer requirements, adhesive specifications, and project documents.

RH Probe Testing Across Southern California:

Reliant Testing Engineers provides concrete moisture testing for commercial, industrial, institutional, and other construction projects throughout Southern California, including the Inland Empire, High Desert, Los Angeles area, and San Diego area.

We coordinate with flooring contractors and project teams to help incorporate testing into construction and installation schedules.

We have extensive experience working in high-seismic zones, remote desert locations, and fast-paced urban construction environments. Our regional coverage allows us to mobilize quickly and provide consistent, code-compliant inspection services wherever your project is located in Southern California.

Schedule Your Concrete Moisture Testing

Planning a commercial flooring installation? Contact Reliant Testing Engineers to discuss your slab, project timeline, and RH testing requirements.

Frequently Asked Questions

ASTM F2170 requires at least 24 hours of equilibration after probe installation before official readings. Scheduling and report turnaround depend on site readiness and project requirements.

Acceptable limits depend on the flooring product, adhesive, and applicable manufacturer specifications. The results should be reviewed against the requirements for the specific flooring system.

Yes. Surface appearance alone does not establish internal moisture conditions. RH probe testing measures relative humidity inside the slab at the prescribed test depth.

Schedule early enough to accommodate probe installation, the equilibration period, official readings, and reporting before your planned flooring installation date.